Frequently Asked Questions (FAQs)
Frequently Asked Questions about OxyData
Most of the other Oxygen Analysers use Electrochemical sensors, which use chemical+oxygen reaction to detect oxygen concentration, and during this process the chemical gets consumed and reduced, so the output changes continuously and that is why oxygen analyzers based on electrochemical sensors are required to be re-calibrated frequently and regularly, and also for the same reason once the chemical is consumed fully, the electrochemical sensor has to be replaced & if not re-calibrated or replaced in time, such oxygen analysers may give wrong measurement of oxygen purity.
In case of OxyData, oxygen concentration (oxygen purity) measurement is done through an Electronic sensor, which has a typical life of more than 5 years, and this sensor does not require re-calibration, so there is no hassle of re-calibration in Oxydata and also ensuring the correct measurement of Oxygen purity all the time.
Also most of the other oxygen analysers measure only oxygen purity, while OxyData can measure Flow rate, Pressure and temperature besides oxygen purity measurement.
Just like Oxygen Purity measurement, other sensors used in OxyData – for Flow rate, Pressure and Temperature are also electronic and have more than 5 years lifetime. And none of these sensors require re-calibration.
The warranty on the OxyData unit inclusive of all sensors is 24 months (2 years).
- OxyData for Oxygen Concentrator Testing (OxyData-B & OxyData-C)
- OxyData for Oxygen Generator Plant Monitoring (OxyData-P & OxyData-G)
- OxyData for Medical Gas Pipeline Monitoring (OxyData-P & OxyData-G)
- OxyData for Oxygen Delivery Monitoring (for Oxygen Bed, ICU, etc.) (OxyData-B & OxyData-C)
- OxyData for Anaesthesia Trolley or Ventilator (FiO2 monitoring) (OxyData-AV)
- OxyData for Oxygen Hood Monitoring (infant baby) (OxyData-A)
- OxyData for Ambient Air Oxygen Monitoring (for Oxygen Leakage or Oxygen Scarcity) (OxyData-A)
No. We have different models for different applications as below:
- OxyData – A for Oxygen Hood Monitoring [infant baby] & Ambient Air Oxygen Monitoring [for Oxygen Leakage or Oxygen Scarcity]
- OxyData – AV for Anaesthesia Trolley or Ventilator [FiO2 monitoring]
- OxyData – B for Oxygen Concentrator Testing & Oxygen Delivery Monitoring [for Oxygen Bed, ICU, etc.]
- OxyData – C for Oxygen Concentrator Testing & Oxygen Delivery Monitoring [for Oxygen Bed, ICU, etc.]
- OxyData – P for Oxygen Generator Plant Monitoring & Medical Gas Pipeline Monitoring
- OxyData – G for Oxygen Generator Plant Monitoring & Medical Gas Pipeline Monitoring
OxyData – C which measures 4 parameters – Oxygen Purity, Flow Rate, Pressure, and Temperature. It’s a Handheld (pocket size) model to continuously monitor Oxygen Concentrator & Oxygen Delivery Monitoring (Oxygen Bed, ICU, etc.) output parameters.
&
OxyData – B which measures Oxygen Purity and Temperature. It’s a Handheld (pocket size) model to continuously monitor Oxygen Concentrator & Oxygen Delivery Monitoring (Oxygen Bed, ICU, etc.) output parameters.
OxyData – P which measures Oxygen Purity and Temperature. It’s a Panel mounted model to continuously monitor Oxygen Generator Plant & Oxygen Pipe Line output parameters.
&
OxyData – G which measures Oxygen Purity and Temperature. It’s a handheld (pocket size) models to Spot-check Oxygen Generator Plant & Oxygen Pipe Line output parameters.
OxyData – P which measures Oxygen Purity and Temperature. It’s a Panel mounted model to continuously monitor Oxygen Generator Plant & Oxygen Pipe Line output parameters.
&
OxyData – G which measures Oxygen Purity and Temperature. It’s a handheld (pocket size) models to Spot-check Oxygen Generator Plant & Oxygen Pipe Line output parameters.
OxyData – C which measures 4 parameters – Oxygen Purity, Flow Rate, Pressure, and Temperature. It’s a Handheld (pocket size) model to continuously monitor Oxygen Concentrator & Oxygen Delivery Monitoring (Oxygen Bed, ICU, etc.) output parameters.
&
OxyData – B which measures Oxygen Purity and Temperature. It’s a Handheld (pocket size) model to continuously monitor Oxygen Concentrator & Oxygen Delivery Monitoring (Oxygen Bed, ICU, etc.) output parameters.
OxyData – AV which measures Oxygen Purity and Temperature. It’s a handheld (pocket size) model for Anaesthesia Trolley or Ventilator (FiO2 monitoring).
OxyData – A which measures Oxygen Purity and Temperature. It’s a handheld (pocket size) model for Oxygen Hood Monitoring (infant baby).
OxyData – A which measures Oxygen Purity and Temperature. It’s a handheld (pocket size) model for Ambient Air Oxygen Monitoring (for Oxygen Leakage or Oxygen Scarcity).
- Wave Visions
- A-12, Durganagar, Bh Tube Company, Old Padra Rd, Vadodara - 390020, India
- 0265 2324681
- marketing@wavevisions.in
- wavevisions@gmail.com